| getSpec VIS 0178 standard - Spectroradiometer for luminance measurements of pulsed light sources | |
|

| 
Request for information

The getSpec VIS 0178 standard is an easy and save to handle and compact VIS spectroradiometer. The included easy-to-use software has the full complement of radiometric and colorometric functions requisite for research, diagnostic, and quality control applications. Its miniaturized design makes it suitable for laboratory as well as industrial use.
The getSpec VIS 0178 standard measures luminance/ radiance and illuminance/ irradiance as well as photosynthetically active radiation (only cw) of continuously pulsed, single pulsed and cw light sources.
Pulsed sources are measured in illuminance mode using the diffuser cap synchronized with the measured lamp cyclus. Radiometric and photometric values are indicated in exposure per puls.
Furthermore colorimetric values (CCT, chromaticity, color purity, dominant wavelength, CRI) and circadian metrics / photosynthetically active radiation are calculated from the spectral data. Therefore it is suited for the test of pulsed light sources such as flash lights, emergency and traffic lights as well as for the measurement of illuminance in rooms, puplic facilites etc.
Advantages
- USB powered
- optical synchronisation to continuously pulsed sources
- no electrical clock signal necessary
- triggering of single pulses
- easy to install and to operate
- powerful but easy to use software
- DLL and measuring firmware commands
Technical parameters
| Optical parameters |
| Spectral range | 380 - 780 nm |
| Spectral resolution | 5nm (FWHM) |
| A/D transformer | 15 bit ADC |
| Spectral accuracy | 1 nm |
| Measuring angle | 1.8° |
| Measuring distance / diameter | 20 cm - 6 mm diameter / 100 cm - 31 mm diameter |
| Measuring values |
| Pulsed sources | spectral radiant exposure, integral luminous and radiant exposure, chromaticity coordinates x, y, u’, v’; correlated color temperature, color purity, color rendering index |
| CW sources | spectral radiance / irradiance
integral luminance / radiance
integral illuminance / irradiance
chromaticity coordinates x, y, u’, v’; correlated color temperature, color purity, color rendering index
circadian metrics, photosynthetically active radiation |
| Measuring ranges / accuracies |
| Illuminance | 200 - 5000 lx s (single flash)
5 - 5000 lx s (flash sequence) |
| Pulse frequency | 0,2 - 20 Hz |
| Luminance | 2 - 7*104 cd/m² (higher values with optional filter) |
| Accuracy (lum., illum.) | 2 % (@ 1000cd/m² and 2856 K) |
| Repeatability (lum., illum.) | 1 % |
| Chromaticity accuracy | 0,002 x, y (@ 2856 K) |
| Color repeatability | 0,0005 x, y |
| Other technical details |
| Dispersive element | Imaging grating (flat field) |
| Detector | Photodiode array with 124 pixel (binned) |
| Power supply | HUB powered |
| PC interface | USB 2.0 full speed |
| Dimensions | 140 mm x 58 mm x 34 mm |
| Weight | 350 g |
| Accessories (included in delivery) | PC Software for Windows 98/2000/XP/Vista, DLL, LabView VI, manual, USB cable, trigger connector, 2 cosine diffusers (irradiance measurement), calibration certificate, tripod, transport box |
| NIST traceable calibration | recommended interval: one year |
|
 |
 |
 |
 |
|

| 
Last change 06/20/2008